EzCad2UNI User’s Manual
notepad, tablet and so on the other software) to direct compilation. Bat is the pure ASCII code text
document, altogether has 3 orders.
1. The examination input port orders IN, for example IN2=1 expression system
examination input port 2, if IN2 is the high level downward carries out, otherwise has waited
for that IN2 turns high.
2. The establishment output port orders OUT, for example OUT4=1, the expression system
establishment output port 4 is the high levels.
3. The time delay orders DELAY, for example DELAY=1000, expression system time
delay 1000 milliseconds.
Auto reset mark count: after the mark stop, the software reset mark count automatic
Disable mark when reach total count: set the total count, when the amount reached, the
software will not continue mark.
User step mark mode: When the marking according to the establishment the Galvo smallest
distance movement, delay fixed time after each movement distance, this function mainly uses in
the strong laser power hitting the depth, the step delay is bigger, the laser marks in the pause
position deeply.
Enable analog current fpk: the time when the analog current is 0 before marking.
Fly Mark
Mark with working line simultaneously. Hit “fly mark” button presenting the dialog box shown in
graph 10-32.
Figure 10-32 Fly mark set dialog box
70